GuardX retainer system

Hold fire doors open. Close them only for a real alarm

Most door holders listen for the alarm on every door, so a vacuum cleaner can set them off. With GuardX, one controller connects to your fire alarm and signals every retainer at once, so doors stay open through everyday noise and close together when it matters.
  • PatentedGB2610424
  • Fits in minutes
  • Category A and B
  • All doors close together
A GuardX retainer mounted on a brushed stainless steel plate at the foot of a wooden fire door, its green indicator lit, while a person vacuums the carpeted floor nearby

How GuardX works

Open every day. Shut the moment it matters.

Fire doors must stay closed to stop fire and smoke spreading, but a closed door is often inconvenient day to day. A retainer is the legal way to keep a fire door open: it holds the door open during normal use and releases it automatically when the fire alarm sounds, so the door closes when it matters. Unlike a wedge or door stop, it never stops a fire door doing its job.

  1. STEP 1

    Your fire alarm activates

    The GuardX controller, installed alongside or wired directly into your fire alarm, is the only component that monitors for an alarm signal.

  2. STEP 2

    The controller signals every door

    The moment the fire alarm activates, a single signal is sent to every GuardX retainer simultaneously.

  3. STEP 3

    Every door closes together

    All connected doors close at the same time when a genuine fire alarm is triggered, remaining securely held open during normal operation.

Because reliability shouldn’t depend on the noise around you

1The controller is installed beside the fire alarm

The controller

One controller for every door

Mounted next to or integrated with your fire alarm, the controller acts immediately when an alarm sounds, sending a signal to every connected door so they close simultaneously and help protect escape routes.

Render of the GuardX controller: a black housing with a white-ringed button on its face, a black aerial rising from the top left and two fitted black cable glands below
  1. Render of the GuardX control unit in exploded view: the matte black enclosure with its white-ringed circular button, the side capsule holding a green indicator above a red one, the straight antenna rising from the top, the patent marking on the face and two hex cable glands below, with its magnetic front cover lifted away to the right

    Discreet by design

    • A clean finish without exposed electronics
    • Magnetic finishing cover
    • Conceals and protects the control unit
  2. Alarm test mode

    • Routine alarm testing without releasing every door
    • Prevents retainers from releasing during weekly alarm tests
    • Returns to normal operation once testing is complete
  3. Pair new doors in seconds

    • Fast commissioning without specialist tools
    • One-button pairing
    • No apps, cables, or programming required
  4. Ready to re-pair

    • Remove and reconnect devices when needed
    • Unpair devices with a single press
    • Ready to pair again in seconds
  5. Render of the GuardX control unit seen close up from its top corner: a black antenna with a knurled metal collar hangs above the recessed gold connector on the top of the enclosure

    Swappable aerial

    • Standard SMA connection for easy upgrades
    • Fit a higher-gain or remote-mounted aerial for extra range
    • Replace in seconds without tools or rewiring
  6. Render of the GuardX control unit with its silver-ringed button and network socket above a mounting bracket, with two disconnected black cable glands in front

    Flexible installation

    • Fast, tidy installation
    • M20 gland entries for secure cable routing
    • Multiple cable entry options
  7. Render of the GuardX controller from the front, with its antenna, green-ringed button and patented marking on top, its network socket between two green terminal blocks, and two fitted black cable glands below

    Future-ready connectivity

    • Extra connectivity when you need it
    • Dedicated alarm connection terminals
    • Additional integration options for future requirements

The retainer

How the retainer holds the door

Press the foot pad to lower the plunger and hold the door open. When the fire alarm activates, power is released, the plunger retracts, and the door closes automatically.

Two renders of the GuardX retainer side by side: on the left its plunger is raised with the green indicator lit, on the right the plunger is pressed down with its rubber foot extended below the housing
  1. Visualisation of the GuardX dual clutch mechanism: a central shaft through a clear block fixed over two compression springs, inside a dark housing with the actuator cylinder beside it

    Always-ready release

    • Reliable release when it matters most
    • Electronic and mechanical release if the door is dragged
    • Works whichever way the door is pushed
  2. No-drag performance

    • Consistent release on any floor
    • Prevents carpet interference
    • Releases if the door is pulled closed
  3. The GuardX retainer with its cover lifted clear of the body: the battery compartment open with a cell standing in its holder and its pull tab upright, the green status panel on the plunger housing to the left

    Long-lasting power

    • Fewer battery changes
    • Powered by two C-cell batteries
    • Optimised for extended battery life
  4. Pairs in seconds

    • Fast, straightforward setup
    • One-button device pairing
    • No apps, tools, or programming required
  5. Efficient by design

    • Proprietary solenoid uses power only when needed
    • Extends battery life
    • Clean, consistent state changes

Why LoRa

One-way LoRa communication delivers reliable, long-range signalling with minimal power consumption

Reliable communication

Long-range wireless signalling designed for dependable operation throughout the building.

Simple installation

Quick pairing with minimal wiring and reduced installation time.

Purpose-built for fire doors

Designed specifically for wireless fire door retention and alarm-triggered release.

Lower lifetime costs

Low power consumption and minimal maintenance requirements.

The Fire Safety Event logo

Launching at The Fire Safety Event

We're launching GuardX at The Fire Safety Event, 27 to 29 April 2027 at the NEC, Birmingham. Meet the team, see the development and discuss your application. GuardX remains in development, and final specifications and availability depend on testing and the required approvals.

Frequently asked questions

Availability

How it works

Setup and everyday use

Safety

Interested in GuardX?

Share your role, country and application with our team.